Discontinued vector network analyzers

General information
Manufacturers of measuring equipment regularly develop and put into production new models vector and scalar analyzers of electrical circuits. After some time, after the start of sales of new models, old models and series are gradually discontinued.
After the cessation of production of a particular model, we continue to support it: service and repair. As a rule, after being discontinued, factory repairs are possible for 5 years or more. After the stock of original microcircuits and spare parts in the service center is exhausted, professional factory repair becomes impossible.
Discontinued models and series of electrical network analyzers
List of discontinued models, indicating the proposed replacement, see the table below.
Model | A photo | Short description |
Vector network analyzers firms Anritsu (out of production) | ||
Anritsu VectorStar MS4642A MS4644A MS4645A MS4647A discontinued |
![]() Product code: 1000107 |
MS4640A Series Vector Network Analyzers Frequency: 70 kHz - 70 GHz (expansion to 110 and 500 GHz is possible). Number of ports: 2. Dynamic range: up to 140 dB. Measurement speed: 20 µs per point. Resolution: up to 100,000 dots. Source power: up to +13 dBm. Receiver linearity: up to +15 dBm compression point at 70 GHz. Parameters of directivity, matching in the source and matching in the load: up to 50 dB. Precision auto-calibration using the module AutoCal. |
Anritsu MN4694B MN4697B
discontinued |
![]() Product code: 1000108 |
MN4690B Series Vector Network Analyzers Frequency: 70 kHz - 20 or 40 GHz (Model MN4694B). Frequency: 70 kHz - 50 or 70 GHz (Model MN4697B). Number of ports: 4. Dynamic range: up to 106 dB. Measurement speed: 28 µs per point. Resolution: up to 100,000 dots. Source power: up to +6 dBm. Directivity, source matching and load matching: 32 dB to 41 dB. Based on Anritsu series vector network analyzer Vector Star. |
Anritsu ME7828A
discontinued |
![]() Product code: 1000109 |
ME7828A Vector Network Analyzer Frequency: 70 kHz - 110 or 500 GHz. Number of ports: 2. Dynamic range: up to 114 dB. Measurement speed: 1 ms per point. Resolution: up to 10,001 dots. Source power: up to +9 dBm. Directivity, source matching and load matching: up to 31 dB. Based on Anritsu series vector network analyzer Vector Star. |
Anritsu ME7808C
discontinued |
![]() Product code: 1000110 |
ME7808C Vector Network Analyzer Frequency: 40 MHz - 110 or 500 GHz. Number of ports: 2. Dynamic range: up to 115 dB. Measurement speed: 15 ms per point. Resolution: up to 1601 dots. Source power: up to +10 dBm. Parameters of directivity, matching in the source and matching in the load: up to 40 dB. Based on Anritsu series vector network analyzer Lightning. |
Anritsu Lightning 37247E 37269E 37297E 37347E 37369E 37397E discontinued |
![]() Product code: 1000111 |
37000E Series Vector Network Analyzers Frequency: 40 MHz - 20, 40 or 65 GHz. Number of ports: 2. Dynamic range: up to 115 dB. Measurement speed: 1.8 ms per point. Resolution: up to 1601 dots. Source power: up to +10 dBm. Parameters of directivity, matching in the source and matching in the load: up to 42 dB. Possibility to measure the parameters of opto-electric converters. Precision auto-calibration using the module AutoCal. USB port. |
Anritsu Lightning 37247D 37347D 37369D 37297D 37397D discontinued |
![]() Product code: 1000112 |
37000D Series Vector Network Analyzers Frequency: 40 MHz - 67 GHz (expansion to 110 and 500 GHz is possible). Number of ports: 2. Dynamic range: up to 118 dB. Measurement speed: 1.8 ms per point. Resolution: up to 1601 dots. Source power: up to +5 dBm. Directionality, source matching and load matching: more than 42 dB. Possibility to measure the parameters of opto-electric converters. Precision auto-calibration using the module AutoCal. |
Anritsu AutoCal 36585 discontinued |
![]() Product code: 1000106 |
AutoCal 36585 Series Modules for Automatic Calibration of Anritsu Vector Network Analyzers Frequency: 70 kHz - 40 GHz (Model 36585K). Frequency: 70 kHz - 70 GHz (Model 36585V). Number of ports: 2. Type K or V connectors. Allows fast automatic calibration with better accuracy than discrete components. Designed for calibration of Anritsu vector analyzers VectorStar series. |
Anritsu AutoCal 36581 36582 discontinued |
![]() Product code: 1000113 |
AutoCal 3658x Series Modules for Automatic Calibration of Anritsu Vector Network Analyzers Frequency: 10 MHz - 20 GHz (models 36581). Frequency: 40 MHz - 40 GHz (model 36582). Number of ports: 2. Type N or K connectors. Allows fast automatic calibration with better accuracy than discrete components. Designed for calibration of Anritsu vector analyzers Lightning series. |
Anritsu VNA Master MS2026B MS2028B discontinued |
![]() Product code: 1000232 |
Handheld Vector Network Analyzers MS2026B, MS2028B Frequency: 5 kHz - 6 or 20 GHz. Number of ports: 2. Dynamic range: up to 80 dB. Measurement speed: 750 µs per point. Resolution: up to 4001 dots. Source power: 0 dBm or -25 dBm. Directivity, source matching and load matching: 32 dB to 42 dB. Support for measurements in coaxial and waveguide paths. Out of production. Replacement: Anritsu MS20xxC VNA Master. |
Anritsu VNA Master MS2024A MS2026A MS2034A MS2036A discontinued |
![]() Product code: 1000233 |
Handheld Vector Network Analyzers MS2024A, MS2026A, MS2034A, MS2036A Frequency: 2 MHz - 4 or 6 GHz. Number of ports: 2. Dynamic range: up to 80 dB. Resolution: up to 551 dots. Source power: 0 dBm or -35 dBm. Directionality, source matching and load matching: more than 42 dB. Models MS2034A and MS2036A contain built-in spectrum analyzer with frequency range: 9 kHz - 4 or 6 GHz respectively. Out of production. Replacement: Anritsu MS20xxC VNA Master. |
Anritsu ME7840A
discontinued |
![]() Product code: 1000189 |
ME7840A Series Vector Network Analyzers Model ME7840A for base stations. Frequency: 800 MHz - 2.4 GHz. Model ME7840/4 for mobile terminals. Frequency: 10 MHz - 6 GHz. Number of ports: 2. Dynamic range: not less than 80 dB. Power sources: 100 W (ME7840A), 5 W (ME7840/4). Directivity and matching parameters: up to 40 dB. Designed for testing power amplifiers of base stations, as well as elements of mobile terminals. Out of production. Replacement: Anritsu MS46122A. |
Anritsu MS4630B discontinued |
![]() Product code: 1000780 |
MS4630B Electrical Network Analyzer Frequency: 10Hz - 300MHz. Number of ports: 2 (optional 3). Dynamic range: up to 120 dB. Measurement speed: 150 µs per point. Resolution: up to 1001 dots. Source power: up to +21 dBm. Ideal for measuring the resonance and group delay characteristics of IF filters, and for evaluating the impedance characteristics of resonators in AV equipment and computers. Out of production. Replacement: Anritsu MS20xxB VNA Master. |
Vector network analyzers firms Rohde & Schwarz (out of production) | ||
Rohde & Schwarz ZVB4, ZVB8, ZVB14, ZVB20 discontinued |
![]() Product code: 1000781 |
ZVB Vector Network Analyzers Frequency: up to 4 GHz, up to 8 GHz, up to 14 GHz or up to 20 GHz (depending on the model). Number of ports: 2 or 4 (for each model). Dynamic range: up to 123 dB. Measurement speed: 4.5 µs per point. Resolution: up to 60,001 dots. Source power: up to +13 dBm. Directionality, source matching and load matching parameters: from 30 dB to 46 dB. Out of production. Replacement: Anritsu MS4640B VectorStar. |
Vector network analyzers firms Keysight (Agilent Technologies) | ||
Agilent N5250C discontinued |
![]() Product code: 1000782 |
Vector network analyzer (complex) N5250C Frequency: 10 MHz to 110 GHz (expansion up to 500 GHz is possible). Number of ports: 2 or 4. Dynamic range: up to 111 dB. Measurement speed: 500 µs per point. Resolution: up to 20,001 dots. Source power: up to -5 dBm. Directivity, source matching and load matching: 35 dB to 45 dB. Based on Agilent PNA series vector network analyzers. Out of production. Replacement: Anritsu MS4640B VectorStar. |
Agilent N5230C discontinued |
![]() Product code: 1000783 |
N5230C PNA-L Vector Network Analyzer Frequency: 300 kHz - 6 or 13 GHz; 10 MHz - 20, 40 or 50 GHz (depending on the model). Number of ports: 2 or 4. Dynamic range: up to 110 dB. Measurement speed: 9 µs per point. Resolution: up to 16,001 dots. Source power: up to +4 dBm. Parameters of directivity, matching in the source and matching in the load: up to 50 dB. Well suited as a basic analyzer for various applications. Out of production. Replacement: Anritsu MS46322A ShockLine. |
Agilent E8361C, E8362C, E8363C, E8364C discontinued |
![]() Product code: 1000784 |
PNA E836xx Vector Network Analyzers Frequency: 10 MHz to 20, 40, 50 or 67 GHz (depending on the model). Number of ports: 2. Dynamic range: up to 123 dB. Measurement speed: 70 µs per point. Resolution: up to 20,001 dots. Source power: up to +3 dBm. Directivity, source matching and load matching: 31 dB to 42 dB. Out of production. Replacement: Anritsu MS4640B VectorStar. |
Agilent 8757D discontinued |
![]() Product code: 1000114 |
8757D Scalar Network Analyzer Frequency: 10 MHz - 18, 20, 26, 40 or 50 GHz (depending on the model). Number of ports: up to 4 external power sensors. Dynamic range: up to 76 dB. Measurement speed: 250 µs per point. Resolution: up to 1601 dots. Power sources: depends on the external generator. Measurements require external sensors, bridges and splitters. |
Agilent N5244A, N5245A discontinued |
![]() Product code: 1000115 |
N5244A, N5245A PNA-X Vector Network Analyzers Frequency: 10 MHz - 43.5 or 50 GHz (depending on the model). Number of ports: 2 or 4. Dynamic range: up to 126 dB. Measurement speed: 37 µs per point. Resolution: up to 32,001 dots. Source power: up to +16 dBm. Parameters of directivity, matching in the source and matching in the load: up to 42 dB. Suitable for demanding testing of active devices up to 50 GHz. |
Agilent N5241A, N5242A discontinued |
![]() Product code: 1000116 |
N5241A, N5242A PNA-X Vector Network Analyzers Frequency: 10 MHz - 13.5 or 26.5 GHz (depending on the model). Number of ports: 2 or 4. Dynamic range: up to 130 dB. Measurement speed: 35 µs per point. Resolution: up to 32,001 dots. Source power: up to +18 dBm. Directionality parameters, matching in the source and matching in the load: up to 48 dB. Suitable for complex testing of active devices. |
Agilent E5071C, E5092A discontinued |
![]() Product code: 1000117 |
E5071C ENA Vector Network Analyzer with E5092A Expansion Module Frequency: 9, 100 or 300 kHz - 4, 6, 8, 14 or 20 GHz (depending on the model). Number of ports: 2 or 4 (up to 16 with expansion module E5091A). Dynamic range: up to 123 dB. Measurement speed: 26 µs per point. Resolution: up to 1601 dots. Source power: up to +10 dBm. Directivity, source matching and load matching: up to 49 dB. Well suited for testing active devices and making multiport measurements. |
Agilent E5061B discontinued |
![]() Product code: 1000118 |
E5061B Vector Network Analyzer Frequency: 5 Hz - 3 GHz. Number of ports: 2. Dynamic range: up to 120 dB. Measurement speed: 160 µs per point. Resolution: up to 1601 dots. Source power: up to +10 dBm. Directivity, source matching and load matching: up to 49 dB. Well suited for testing passive devices and testing at low frequency (from 5 Hz). |
Agilent E5061A, E5062A discontinued |
![]() Product code: 1000119 |
ENA-L Series Vector Network Analyzers Frequency: 300 kHz - 1.5 or 3 GHz (depending on the model). Number of ports: 2. Dynamic range: up to 120 dB. Measurement speed: 200 µs per point. Resolution: up to 1601 dots. Source power: up to +10 dBm. Directivity, source matching and load matching: up to 49 dB. Port impedance 50 or 75 ohms. Determining the location of inhomogeneities in cables. Electronic calibration (ECal). |
Other discontinued models: Advantest R3765CG, Advantest R3767CG, Agilent 4395A, Agilent 4396B, Agilent 8753ES used, Agilent 8753ET used, Agilent E5061A, Agilent E5100A used, Agilent E8361A, Anritsu 37247D, Anritsu 54137A, Anritsu 56100A, Anritsu MS4630B, R&S ZVK, R&S ZVM bu.
New models and series of electrical network analyzers
New models network analyzers are presented in detail on this page.