Laboratory multimeters
Multimeters are used everywhere to measure basic electrical quantities: voltage, current, resistance, frequency, etc. There are two main classes of multimeters: hand-held multimeters (with relatively low accuracy) and laboratory multimeters (medium and high accuracy classes).
Tehencom company specializes in the supply of accurate (precision) benchtop laboratory multimeters. You can buy multimeters from us at a good price from a warehouse in Kyiv or on order. We carry out delivery throughout Ukraine. If you need technical advice or assistance in comparing the characteristics of multimeters, you can contact our technical specialist: contacts (consultation is free). For a complete list of excellent laboratory multimeters for all kinds of measurements, see these catalogs:
Catalog of Tektronix and Keithley devices (2019) (in Russian) (140 pages; 14 MB)
Full catalog of Keithley company (2013) (in Russian) (108 pages; 5.4 MB)
The best models in terms of price / features ratio
The table below shows popular models of precision laboratory multimeters that are most interesting in terms of cost, performance and workmanship. All series of offered multimeters (about 30 models) are presented here.
Model | A photo | Short description |
The best models of precision laboratory multimeters in terms of price / performance ratio | ||
Keithley DMM6500 |
Product code: 1000683 |
Keithley DMM6500 Laboratory Multimeter Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0025%. Voltage measurement range: 0.1 µV to 1010 V. Current measurement range: 10 pA to 10.1 A. Resistance measurement range: 1 µΩ to 120 GΩ. Capacitance measurement range: 0.1pF to 120uF. Up to 21,000 measurements per second. Connection of signals on the front and rear panels. Digitization of voltage and current signals: 16 bits (from 1 kS/s to 1 MS/s). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), capacitance, period, frequency, diode test, temperature (using thermocouples, thermistors and RTDs), etc. 10 channels of voltage or resistance (optional) 2000-SCAN). Free computer software, LabVIEW, IVI-C, IVI-COM drivers. 12.7 cm widescreen touchscreen (800 x 480 resolution). Weight: 4.54 kg. Interfaces: Ethernet/LXI and USB (standard); IEEE-488.2 (GPIB), RS-232 and TSP-Link (optional). Basic multimeter for laboratory and production |
Keithley DAQ6510 |
Product code: 1000684 |
Keithley DAQ6510 Laboratory Multimeter with Integrated Data Acquisition, Switching and Channel Scanning Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0025%. Voltage measurement range: 0.1 µV to 1010 V. Current measurement range: 10 pA to 10.1 A. Resistance measurement range: 1 µΩ to 120 GΩ. Capacitance measurement range: 0.1pF to 120uF. Digitization of voltage and current signals: 16 bits (from 1 kS/s to 1 MS/s). 12 types of switching and control modules. Possibility to install two modules. Depending on the type, the modules may contain: a switch for 20, 32 or 40 input channels, 16 digital and 2 analog control outputs, a 6x8 arbitrary switching matrix, a 3.5 GHz microwave switch, etc. The maximum number of channels: 80. 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), capacitance, period, frequency, diode test, temperature (using thermocouples, thermistors and RTDs), etc. Free computer software, drivers LabVIEW, IVI-C, IVI-COM. 12.7 cm widescreen touchscreen (800 x 480 resolution). Weight: 4.54 kg. Interfaces: Ethernet/LXI and USB (standard); IEEE-488.2 (GPIB), RS-232 and TSP-Link (optional). Multifunctional data acquisition system with 6.5 digit multimeter |
Comparison of the best models by price level
The main influence on the cost of a laboratory multimeter is its accuracy class, which is closely related to such a concept as the number of discharges. In addition, all precision laboratory multimeters can be equipped with additional useful options and accessories that significantly expand the functionality of the device, but at the same time increase its cost.
You can quickly get accurate prices for the models you are interested in by sending us a request by E-mail. And to buy a good package cheaper, look this material.
All series of laboratory multimeters
The table below presents a wide range of new precision laboratory multimeters to solve any modern application. In the table, the devices are sorted by increasing the number of displayed digits (from 5.5 to 8.5) and increasing the accuracy class. If you need detailed pricing information or technical advice on choosing the best multimeter for your application, just call us or write to us at E-mail and we will be happy to answer your questions.
Model | A photo | Short description |
Multimeters of the Keithley company | ||
Keithley 2110 |
Product code: 1000685 |
Budget laboratory multimeter Keithley 2110 Resolution: 5.5 digit. Basic Accuracy (DCV): 0.012%. Voltage measurement range: 1 µV to 1000 V. Current measurement range: 0.1 µA to 10 A. Resistance measurement range: 1 mΩ to 100 MΩ. Capacitance measurement range: 10 pF to 100 uF. Speed: 50,000 measurements per second. External trigger input (BNC connector). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, capacitance, temperature (using thermocouples and thermistors), diode test, break detection, etc. Programmable filter. 7 mathematical operations on measurement results. Computer software. Interfaces: standard USB-TMC, optional IEEE-488.2 (GPIB). Weight: 2.23 kg. Budget multimeter with good accuracy and feature set |
Keithley DMM6500 |
Product code: 1000683 |
Keithley DMM6500 Laboratory Multimeter Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0025%. Voltage measurement range: 0.1 µV to 1010 V. Current measurement range: 10 pA to 10.1 A. Resistance measurement range: 1 µΩ to 120 GΩ. Capacitance measurement range: 0.1pF to 120uF. Up to 21,000 measurements per second. Connection of signals on the front and rear panels. Digitization of voltage and current signals: 16 bits (from 1 kS/s to 1 MS/s). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), capacitance, period, frequency, diode test, temperature (using thermocouples, thermistors and RTDs), etc. 10 channels of voltage or resistance (optional) 2000-SCAN). Free computer software, LabVIEW, IVI-C, IVI-COM drivers. 12.7 cm widescreen touchscreen (800 x 480 resolution). Weight: 4.54 kg. Interfaces: Ethernet/LXI and USB (standard); IEEE-488.2 (GPIB), RS-232 and TSP-Link (optional). Basic multimeter for laboratory and production |
Keithley 2000 2000-SCAN |
Product code: 1000686 |
Keithley 2000 and 2000-SCAN Laboratory Multimeters Resolution: 6.5 digit. Basic Accuracy (DCV): 0.002%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 100 µΩ to 100 MΩ. Speed: 2,000 measurements per second. Compatible with Fluke 8840/42 commands. Model 2000-SCAN contains scanner board for 10 channels. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples), diode test, open detection, dB, dBm. Interfaces: IEEE-488.2 (GPIB), RS-232. Weight: 2.9 kg. Basic laboratory multimeter for a wide range of applications |
Keithley 2100 |
Product code: 1000687 |
Laboratory multimeter Keithley 2100 Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0038%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 100 µΩ to 100 MΩ. Speed: 2,000 measurements per second. Connection of signals on the front and rear panels. 11 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, diode test. Programmable filter. Computer software. Interfaces: USB-TMC. Weight: 4.1 kg. Basic laboratory multimeter with USB connection |
Keithley DMM7510 |
Product code: 1000688 |
Keithley DMM7510 Graphical Laboratory Multimeter with Storage Oscilloscope Function Resolution: 7.5 digit. Basic Accuracy (DCV): 0.0014%. Voltage measurement range: 10 nV to 1010 V. Current measurement range: 1 pA to 10.1 A. Resistance measurement range: 0.1 μΩ to 1.2 GΩ. Capacitance measurement range: 0.1pF to 1200uF. Speed: 24,000 measurements per second. Connection of signals on the front and rear panels. Speed digitization of voltage and current signals: 10 kSa/s to 1 MSa/s. Digitization of voltage and current signals: from 12 bits to 18 bits. 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, dry contact), capacitance, frequency, period, temperature (using thermocouples, thermistors and RTDs). Free PC software and drivers LabVIEW, IVI. 12.7 cm widescreen touchscreen (800 x 480 resolution). Interfaces: IEEE-488.2 (GPIB), Ethernet/LXI, USB, TSP-Link. Weight: 4.08 kg. Accurate digital multimeter with touch control |
Keithley 2010 |
Product code: 1000689 |
Laboratory multimeter for production lines Keithley 2010 Resolution: 7.5 digit. Basic Accuracy (DCV): 0.0018%. Voltage measurement range: 10 nV to 1000 V. Current measurement range: 1 nA to 3 A. Resistance measurement range: 1 μΩ to 100 MΩ. Speed: 2,000 measurements per second. Ability to measure the ratio of signals. Scanner module for 10 channels (option). Built-in memory: 1024 results. 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, dry contact), frequency, period, temperature (using thermocouples and resistance temperature detectors (RTD)), diode test, open detection, ratio two values, etc. Interfaces: IEEE-488.2 (GPIB), RS-232. Weight: 2.9 kg. Accurate multimeter for product testing on production lines |
Keithley 2001 |
Product code: 1000690 |
Keithley 2001 Laboratory Multimeter Resolution: 7.5 digit. Basic Accuracy (DCV): 0.0018%. Voltage measurement range: 10 nV to 1100 V. Current measurement range: 10 pA to 2.1 A. Resistance measurement range: 1 μΩ to 1 GΩ. Speed: 2,000 measurements per second. Scanner module for 10 channels (option). Built-in memory: 8K (optional up to 128K). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples and resistance temperature detectors (RTD)), crest factor, peak level measurement, etc. Interfaces: IEEE-488.2 (GPIB). Weight: 4.2 kg. Precision laboratory multimeter for a wide range of applications |
Keithley 2002 |
Product code: 1000691 |
Keithley 2002 Precision Laboratory Multimeter Resolution: 8.5 digit. Basic Accuracy (DCV): 0.0006%. Voltage measurement range: 1 nV to 1100 V. Current measurement range: 10 pA to 2.1 A. Resistance measurement range: 100 nΩ to 1 GΩ. Speed: 2,000 measurements per second. Compatible with Agilent 3458A commands. Scanner module for 10 channels (option). Built-in memory: 8K (optional up to 128K). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples and resistance temperature detectors (RTD)), crest factor, peak level measurement, etc. Interfaces: IEEE-488.2 (GPIB). Weight: 4.2 kg. Precision multimeter for metrology laboratories |
Keithley 2015 2015-P 2016 2016-P |
Product code: 1000692 |
Keithley 2015, 2015-P, 2016, 2016-P Laboratory Multimeters with Built-in Audio Analyzer and THD Multimeter + Distortion Analysis + 4V Audio Generator (Model 2015). Multimeter + Distortion Analysis + 4V Audio Generator + Harmonics (Model 2015-P). Multimeter + Distortion Analysis + 9.5V Audio Generator (Model 2016). Multimeter + Distortion Analysis + 9.5V Audio Generator + Harmonics (Model 2016-P). Multimeter resolution: 6.5 digit. Basic Multimeter Accuracy (DCV): 0.002%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 100 µΩ to 100 MΩ. Speed: 2,000 measurements per second. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples), diode test, open detection, dB, dBm. The built-in distortion analyzer measures: THD, THD+Noise and SINAD. The built-in harmonic analyzer measures individual harmonic levels. Audio analyzer frequency range: 20 Hz - 20 kHz. Five standard audio filters. Interfaces: IEEE-488.2 (GPIB), RS-232. Weight: 4.2 kg. An excellent tool for developing and configuring devices in the audio range |
Multifunctional data acquisition and control systems of the Keithley company | ||
Keithley DAQ6510 |
Product code: 1000684 |
Keithley DAQ6510 Laboratory Multimeter with Integrated Data Acquisition, Switching and Channel Scanning Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0025%. Voltage measurement range: 0.1 µV to 1010 V. Current measurement range: 10 pA to 10.1 A. Resistance measurement range: 1 µΩ to 120 GΩ. Capacitance measurement range: 0.1pF to 120uF. Digitization of voltage and current signals: 16 bits (from 1 kS/s to 1 MS/s). 12 types of switching and control modules. Possibility to install two modules. Depending on the type, the modules may contain: a switch for 20, 32 or 40 input channels, 16 digital and 2 analog control outputs, a 6x8 arbitrary switching matrix, a 3.5 GHz microwave switch, etc. The maximum number of channels: 80. 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), capacitance, period, frequency, diode test, temperature (using thermocouples, thermistors and RTDs), etc. Free computer software, drivers LabVIEW, IVI-C, IVI-COM. 12.7 cm widescreen touchscreen (800 x 480 resolution). Weight: 4.54 kg. Interfaces: Ethernet/LXI and USB (standard); IEEE-488.2 (GPIB), RS-232 and TSP-Link (optional). Multifunctional data acquisition system with 6.5 digit multimeter |
Keithley 2700 2701 2750 |
Product code: 1000693 |
Keithley 2700, 2701, 2750 laboratory multimeters with built-in data acquisition, switching and channel scanning Resolution: 6.5 digit. Basic Accuracy (DCV): 0.002%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 1 µΩ to 100 MΩ. Speed: 3,500 measurements per second. 12 types of switching and control modules. Model 2700, 2701 can install up to two modules, model 2750 up to five modules. Depending on the type, the modules may contain: a switch for 32 or 40 input channels, 16 digital and 2 analog control outputs, a 6x8 arbitrary switching matrix, a 3.5 GHz microwave switch, etc. The maximum number of channels: 200. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, "dry contact"), frequency, period, temperature (using thermocouples, thermistors and RTDs), break detection, etc. Interfaces: IEEE- 488.2 (GPIB) (on models 2700, 2750), Ethernet (on model 2701), RS-232. Compact measuring system with the possibility of switching and control |
Keithley 3700A |
Product code: 1000694 |
Keithley 3700A Series Lab Multimeters with Integrated Data Acquisition, Switching, and Channel Scanning Resolution: 7.5 digit. Basic Accuracy (DCV): 0.002%. Voltage measurement range: 10 nV to 300 V. Current measurement range: 1 pA to 3 A. Resistance measurement range: 100 nΩ to 120 MΩ. Speed: 14,000 measurements per second. 10 types of switching and control modules. The Model 3706A accepts up to six modules. Depending on the type, the modules may contain: a switcher for 20, 30 or 40 input channels, a multifunctional control unit, a 6x16 or 4x28 random switching matrix, etc. The maximum number of channels: 576. Several 3700A series units can be interconnected and controlled as one device. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, "dry contact"), frequency, period, temperature (using thermocouples, thermistors and RTDs), break detection, etc. Interfaces: USB- TMC, IEEE-488.2 (GPIB), Ethernet. Powerful measuring system with switching and control capability |
Calibrators-multimeters (SMUs) of the Keithley company | ||
Keithley 2450 |
Product code: 1000695 |
Keithley 2450 Touch Calibrator Multimeter (SMU) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 500 nV to 200 V (generation), 10 nV to 210 V (measurement). Current: 500 fA to 1 A (generation), 10 fA to 1.05 A (measurement). Resistance: 1 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). Speed: up to 3,130 measurements per second. Formation of a series of control points. Free PC software and drivers LabVIEW, IVI. 12.7 cm widescreen touchscreen (800 x 480 resolution). Interfaces: IEEE-488.2 (GPIB), Ethernet/LXI, USB, TSP-Link. Weight: 4.04 kg. Convenient, accurate and affordable touch-controlled device |
Keithley 2401 |
Product code: 1000696 |
Keithley 2401 Multimeter Calibrator (SMU) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 20 V (generation), 1 µV to 21 V (measurement). Current: 50 pA to 1 A (generation), 10 pA to 1.05 A (measurement). Resistance: from 100 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 3.21 kg. Inexpensive Low Voltage Calibrator Multimeter (SMU) up to 20V |
Keithley 2400 2400-C |
Product code: 1000697 |
Keithley 2400 and 2400-C SMU Calibrators Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 200 V (generation), 1 µV to 210 V (measurement). Current: 50 pA to 1 A (generation), 10 pA to 1.05 A (measurement). Resistance: from 100 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Automatic testing of connection contacts (Model 2400-C). Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 3.21 kg. Basic calibrator-multimeter (SMU) for a wide range of applications |
Keithley 2410 2410-C |
Product code: 1000698 |
Keithley 2410 and 2410-C High Voltage Calibrators/Multimeters (SMUs) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 1000 V (generation), from 1 µV to 1100 V (measurement). Current: 50 pA to 1 A (generation), 10 pA to 1.05 A (measurement). Resistance: from 100 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Automatic testing of connection contacts (Model 2410-C). Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 3.21 kg. High voltage multimeter calibrator (SMU) up to 1000 V |
Keithley 2425 2425-C |
Product code: 1000699 |
Powerful (up to 100 W) Keithley 2425 and 2425-C Calibrators/Multimeters (SMUs) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 100 V (generation), 1 µV to 105 V (measurement). Current: 500 pA to 3 A (generation), 100 pA to 3.15 A (measurement). Resistance: 10 µΩ to 20 MΩ (measurement). Output power: up to 100 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Automatic testing of connection contacts (Model 2425-C). Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 4.1 kg. Powerful multimeter calibrator (SMU) up to 100 W |
Multimeters of the Tektronix company | ||
Tektronix DMM4020 |
Product code: 1000700 |
Tektronix DMM4020 Budget Lab Multimeter Resolution: 5.5 digit. Basic Accuracy (DCV): 0.018%. Voltage measurement range: 1 μV to 1000 V. Current measurement range: 1 nA to 10 A. Resistance measurement range: 1 mΩ to 100 MΩ. Speed: 100 measurements per second. Diode and continuity test, frequency measurement, 4-wire resistance measurement (2x4), DC leakage measurement, six dedicated buttons for quick access to instrument settings, limit comparison mode for pass/fail tests . National Instrument LabVIEW SignalExpress TE Limited Edition PC software. Interfaces: RS-232 plus USB to RS-232 adapter as standard. Weight: 2.1 kg. Budget multimeter with good accuracy and feature set |
Tektronix DMM4040 DMM4050 |
Product code: 1000701 |
Tektronix DMM4040 and DMM4050 Laboratory Multimeters Resolution: 6.5 digit. Basic Accuracy (DCV): 0.004% (model DMM4040). Basic Accuracy (DCV): 0.003% (model DMM4050). Voltage measurement range: 100 nV to 1000 V. Current measurement range: 100 pA to 10 A. Resistance measurement range: 10 μΩ to 1 GΩ. Speed: 1000 measurements per second. Diode test and continuity test, frequency and period measurement, 4-wire resistance measurement (2x4), Trendplot automatic data recording mode, measurement statistics, histogram plotting mode. Temperature and capacity measurement (only DMM4050). National Instrument LabVIEW SignalExpress TE PC software. Interfaces: USB (for flash drive), IEEE-488.2 (GPIB), Ethernet, RS-232 plus USB to RS-232 adapter as standard. Weight: 3.6 kg. Basic laboratory multimeters for a wide range of applications |
Tektronix MDO3012 MDO3014 MDO3022 MDO3024 MDO3032 MDO3034 MDO3052 MDO3054 MDO3102 MDO3104 |
Product code: 1000018 |
Oscilloscopes with built-in spectrum analyzer, oscillator, logic analyzer, protocol analyzer, voltmeter and frequency counter Tektronix MDO3000 series from 100 MHz to 1 GHz 100 MHz, 2.5 GS/s, 2 channels + spectrum analyzer 9 kHz - 100 MHz (model MDO3012). 100 MHz, 2.5 GS/s, 4 channels + spectrum analyzer 9 kHz - 100 MHz (model MDO3014). 200 MHz, 2.5 GS/s, 2 channels + spectrum analyzer 9 kHz - 200 MHz (model MDO3022). 200 MHz, 2.5 GS/s, 4 channels + spectrum analyzer 9 kHz - 200 MHz (model MDO3024). 350 MHz, 2.5 GS/s, 2 channels + spectrum analyzer 9 kHz - 350 MHz (model MDO3032). 350 MHz, 2.5 GS/s, 4 channels + spectrum analyzer 9 kHz - 350 MHz (model MDO3034). 500 MHz, 2.5 GS/s, 2 channels + spectrum analyzer 9 kHz - 500 MHz (model MDO3052). 500 MHz, 2.5 GS/s, 4 channels + spectrum analyzer 9 kHz - 500 MHz (model MDO3054). 1 GHz, 5 GS/s, 2 channels + spectrum analyzer 9 kHz - 1 GHz (model MDO3102). 1 GHz, 5 GS/s, 4 channels + spectrum analyzer 9 kHz - 1 GHz (model MDO3104). Record length: 10M points per channel. Vertical resolution: 8 bits (11 bits in high resolution mode). Sensitivity: 1 mV/div to 10 V/div with calibrated fine tuning. Continuous waveform capture rate: up to 280,000 wfms/s. Spectrum analyzer bandwidth extension to 9 kHz - 3 GHz (option MDO3SA). Built-in digital voltmeter and frequency counter (included as standard). Additional options: generator of standard and arbitrary signals, logic analyzer for 16 digital channels, protocol analyzer: I2C, SPI, RS-232/422/485/UART, USB 2.0, CAN, LIN, FlexRay, MILSTD-1553, audio buses and others. 22.9 cm screen (800 x 480 resolution). Interfaces: USB, Ethernet, XGA external monitor. Weight: 4.2 kg. Dimensions: 203 x 417 x 147 mm. Working temperature: from -10°С to +55°С. An indispensable tool in the design, debugging and repair of modern complex electronic systems |
Parametric analyzers of the Keithley company | ||
Keithley 4200A-SCS |
Product code: 1000702 |
Keithley 4200A-SCS Parametric Analyzer Current-voltage characteristic (CVC) range: up to 210 V, up to 1 A. Capacitance-voltage characteristic (CVC) frequency range: from 1 kHz to 10 MHz. Pulse current-voltage characteristic range: ±40 V, ±800 mA, 200 MSa/s. Current resolution: up to 0.1 pA. Connection diagram: 2-wire and 4-wire. Allows you to measure the I-V characteristics, the complex resistance to alternating current, register signals and measure the I-V characteristics of transients. 39.6 cm color touch screen (1920 x 1080 resolution). Interfaces: USB, Ethernet (LAN), IEEE-488.2 (GPIB), RS-232, SVGA. Weight: 29.7 kg. Dimensions: 436 x 223 x 565 mm. Working temperature: from +10°С to +40°С. Accurate characterization of semiconductors and materials |
LCR (RLC) meters of the Sourcetronic company | ||
Sourcetronic ST2829A ST2829B ST2829C |
Product code: 1000703 |
ST2829 Series LCR Sourcetronic Laboratory Meters Frequency: 20Hz - 300KHz (Model ST2829A) Frequency: 20Hz - 500kHz (Model ST2829B) Frequency: 20Hz - 1MHz (Model ST2829C) Basic Accuracy: 0.05%. Inductance measurement range: 0.00001 µH to 9.9999 kH. Capacitance measurement range: 0.00001 pF to 9.99999 F. Resistance measurement range: 0.00001 Ω to 99.9999 MΩ. Q-factor measurement range: from 0.0001 to 99999. Measuring voltage 5 mV - 10 V (RMS), measuring current 50 μA - 100 mA (RMS). Built-in 10V/100mA DC bias voltage source. 17.7 cm color graphics screen (800 x 480 resolution). Weight: 13 kg. Interfaces: Ethernet/LXI, USB, RS-232 (standard); IEEE-488.2 (GPIB) (option). Precision LCR Meters with Maximum Capabilities |
Testers of batteries and galvanic cells of the ITECH company | ||
ITECH IT5101 IT5101E |
Product code: 1000577 |
Testers of batteries and galvanic cells ITECH IT5100 Voltage measurement range: 10 µV to 300 V. Resistance measurement range: 150 µΩ to 3 kΩ (Model IT5101). Resistance measurement range: 15 mΩ to 3 Ω (model IT5101E). Support for all types of batteries and galvanic cells. Simultaneous measurement of voltage and resistance (up to 125 per second). Accurate 4-wire measurements. Function pass/fail. Statistical processing and storage of results. 10.9 cm color screen (480 x 272 resolution). Interfaces: USB, Ethernet (LAN), IEEE-488.2 (GPIB). Weight: 2.4 kg. Dimensions: 384 x 230 x 105 mm. Working temperature: from +5°С to +40°С. Checking batteries during production, storage and operation |
Economy offer
Tehencom company offers both brand new digital laboratory multimeters, as well as used, exhibition and demonstration items. The cost of these devices can be 1.5 - 2 times lower than the cost of new ones. All devices offered in this category are 100% operational, meet the technical requirements of the manufacturer and are provided 1 year warranty.
Below are some of the many showcase and demo fixtures we offer.
Model | A photo | Short description |
Multimeters of the Keithley company (refurbished) | ||
Keithley 2000 |
Desktop multimeter. 100 mV - 1 kV. 6.5 digit. Accuracy: 0.0015%. DCV, ACV, R, wire break, diode, DCA, ACA, TRMS. |
|
Keithley 2700/2701 |
Desktop multimeter. 100 mV - 1 kV. 6.5 digit. Accuracy: 10ppm. DCV, ACV, R, DCA, ACA, frequency, temperature. Control and registration modules. |
|
Keithley 2010 |
Desktop multimeter. 100 mV - 1 kV. 7.5 digit. Accuracy: 10ppm. DCV, ACV, R, DCA, ACA, frequency, period, temperature. |
|
Keithley 2750 |
Desktop multimeter. 100 mV - 1 kV. 6.5 digit. Accuracy: 10ppm. DCV, ACV, R, DCA, ACA, frequency, temperature. Control and registration modules. |
|
Keithley 2015 / 2016 |
Desktop multimeter. 100 mV - 750 V. 6.5 digit Accuracy: 30ppm. DCV, ACV, DCA, ACA, frequency, diode, temperature, harmonic distortion. |
|
Keithley 2001 |
Desktop multimeter. 200 mV - 1 kV. 7.5 digit. Accuracy: 27ppm. DCV, ACV, R, DCA, ACA. |
|
Multimeters of the Agilent Technologies company (refurbished) | ||
Agilent 34401A |
Desktop multimeter. 100 mV - 1 kV. 6.5 digit. Accuracy: 0.0035%. DCV, ACV, R, wire break, diode, DCA, ACA, frequency, TRMS. |
|
Agilent 34420A |
Desktop multimeter. 1 mV - 100 V. 7.5 digit Accuracy: 0.0002%. Measurement: DCV, R, temperature. |
|
Agilent 3458A |
Desktop multimeter. 100 mV - 1 kV. 8.5 digit. Accuracy: 0.5 - 2.5ppm. Measurement: DCV, ACV, R, diode, DCA, ACA, frequency, period. |
|
Multimeters of the Fluke company (refurbished) | ||
Fluke 45 |
Desktop multimeter. 0 V - 1 kV. 5 digit. Accuracy: 0.025%. Measurement: DCV, ACV, R, DCA, ACA, frequency, TRMS, temperature, dBm. |
|
Fluke 8508A |
Desktop multimeter. 200 mV - 1 kV. 8.5 digit. Accuracy: 12ppm. Measurement: DCV, ACV, R, DCA, ACA, temperature. |