Tehencom company supplies measuring equipment of the brand Keithley: multimeters, generators, signal sources, data acquisition devices, etc. We offer a full range of Keithley measuring and control devices, as well as provide service, warranty and post-warranty service. Company Keithley (www.keithley.com), founded in the late 1950s, is the world's leading manufacturer of precision equipment for the laboratory and industry. The main production facilities and development laboratories are located in the USA. Keithley products are sold in more than 80 countries, and the annual turnover in 2010 exceeded $120,000,000. Tektronix. |
Keithley Distributor Certificate (1 page; 225 KB)
Catalog of Tektronix and Keithley devices (2019) (in Russian) (140 pages; 14 MB)
Full catalog of Keithley instruments (in Russian) (108 pages; 5.4 MB)
Below are the most popular brand equipment models Keithley. Regarding prices and delivery times for the entire range of instrumentation, simply call us or write to us at E-mail and we will be happy to answer your questions.
Model | A photo | Short description |
Multimeters of the Keithley brand | ||
Keithley 2110 |
Product code: 1000685 |
Budget laboratory multimeter Keithley 2110 Resolution: 5.5 digit. Basic Accuracy (DCV): 0.012%. Voltage measurement range: 1 µV to 1000 V. Current measurement range: 0.1 µA to 10 A. Resistance measurement range: 1 mΩ to 100 MΩ. Capacitance measurement range: 10 pF to 100 uF. Speed: 50,000 measurements per second. External trigger input (BNC connector). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, capacitance, temperature (using thermocouples and thermistors), diode test, break detection, etc. Programmable filter. 7 mathematical operations on measurement results. Computer software. Interfaces: standard USB-TMC, optional IEEE-488.2 (GPIB). Weight: 2.23 kg. Budget multimeter with good accuracy and feature set |
Keithley DMM6500 |
Product code: 1000683 |
Keithley DMM6500 Laboratory Multimeter Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0025%. Voltage measurement range: 0.1 µV to 1010 V. Current measurement range: 10 pA to 10.1 A. Resistance measurement range: 1 µΩ to 120 GΩ. Capacitance measurement range: 0.1pF to 120uF. Up to 21,000 measurements per second. Connection of signals on the front and rear panels. Digitization of voltage and current signals: 16 bits (from 1 kS/s to 1 MS/s). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), capacitance, period, frequency, diode test, temperature (using thermocouples, thermistors and RTDs), etc. 10 channels of voltage or resistance (optional) 2000-SCAN). Free computer software, LabVIEW, IVI-C, IVI-COM drivers. 12.7 cm widescreen touchscreen (800 x 480 resolution). Weight: 4.54 kg. Interfaces: Ethernet/LXI and USB (standard); IEEE-488.2 (GPIB), RS-232 and TSP-Link (optional). Basic multimeter for laboratory and production |
Keithley 2000 2000-SCAN |
Product code: 1000686 |
Keithley 2000 and 2000-SCAN Laboratory Multimeters Resolution: 6.5 digit. Basic Accuracy (DCV): 0.002%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 100 µΩ to 100 MΩ. Speed: 2,000 measurements per second. Compatible with Fluke 8840/42 commands. Model 2000-SCAN contains scanner board for 10 channels. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples), diode test, open detection, dB, dBm. Interfaces: IEEE-488.2 (GPIB), RS-232. Weight: 2.9 kg. Basic laboratory multimeter for a wide range of applications |
Keithley 2100 |
Product code: 1000687 |
Laboratory multimeter Keithley 2100 Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0038%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 100 µΩ to 100 MΩ. Speed: 2,000 measurements per second. Connection of signals on the front and rear panels. 11 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, diode test. Programmable filter. Computer software. Interfaces: USB-TMC. Weight: 4.1 kg. Basic laboratory multimeter with USB connection |
Keithley DMM7510 |
Product code: 1000688 |
Keithley DMM7510 Graphical Laboratory Multimeter with Storage Oscilloscope Function Resolution: 7.5 digit. Basic Accuracy (DCV): 0.0014%. Voltage measurement range: 10 nV to 1010 V. Current measurement range: 1 pA to 10.1 A. Resistance measurement range: 0.1 μΩ to 1.2 GΩ. Capacitance measurement range: 0.1pF to 1200uF. Speed: 24,000 measurements per second. Connection of signals on the front and rear panels. Speed digitization of voltage and current signals: 10 kSa/s to 1 MSa/s. Digitization of voltage and current signals: from 12 bits to 18 bits. 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, "dry contact"), capacitance, frequency, period, temperature (using thermocouples, thermistors and RTDs). Free PC software and drivers LabVIEW, IVI. 12.7 cm widescreen touchscreen (800 x 480 resolution). Interfaces: IEEE-488.2 (GPIB), Ethernet/LXI, USB, TSP-Link. Weight: 4.08 kg. Accurate digital multimeter with touch control |
Keithley 2010 |
Product code: 1000689 |
Laboratory multimeter for production lines Keithley 2010 Resolution: 7.5 digit. Basic Accuracy (DCV): 0.0018%. Voltage measurement range: 10 nV to 1000 V. Current measurement range: 1 nA to 3 A. Resistance measurement range: 1 μΩ to 100 MΩ. Speed: 2,000 measurements per second. Ability to measure the ratio of signals. Scanner module for 10 channels (option). Built-in memory: 1024 results. 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, "dry contact"), frequency, period, temperature (using thermocouples and resistance temperature detectors (RTD)), diode test, open detection, ratio two values, etc. Interfaces: IEEE-488.2 (GPIB), RS-232. Weight: 2.9 kg. Accurate multimeter for product testing on production lines |
Keithley 2001 |
Product code: 1000690 |
Keithley 2001 Laboratory Multimeter Resolution: 7.5 digit. Basic Accuracy (DCV): 0.0018%. Voltage measurement range: 10 nV to 1100 V. Current measurement range: 10 pA to 2.1 A. Resistance measurement range: 1 μΩ to 1 GΩ. Speed: 2,000 measurements per second. Scanner module for 10 channels (option). Built-in memory: 8K (optional up to 128K). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples and resistance temperature detectors (RTD)), crest factor, peak level measurement, etc. Interfaces: IEEE-488.2 (GPIB). Weight: 4.2 kg. Precision laboratory multimeter for a wide range of applications |
Keithley 2002 |
Product code: 1000691 |
Keithley 2002 Precision Laboratory Multimeter Resolution: 8.5 digit. Basic Accuracy (DCV): 0.0006%. Voltage measurement range: 1 nV to 1100 V. Current measurement range: 10 pA to 2.1 A. Resistance measurement range: 100 nΩ to 1 GΩ. Speed: 2,000 measurements per second. Compatible with Agilent 3458A commands. Scanner module for 10 channels (option). Built-in memory: 8K (optional up to 128K). 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples and resistance temperature detectors (RTD)), crest factor, peak level measurement, etc. Interfaces: IEEE-488.2 (GPIB). Weight: 4.2 kg. Precision multimeter for metrology laboratories |
Keithley 2015 2015-P 2016 2016-P |
Product code: 1000692 |
Keithley 2015, 2015-P, 2016, 2016-P Laboratory Multimeters with Built-in Audio Analyzer and THD Multimeter + Distortion Analysis + 4V Audio Generator (Model 2015). Multimeter + Distortion Analysis + 4V Audio Generator + Harmonics (Model 2015-P). Multimeter + Distortion Analysis + 9.5V Audio Generator (Model 2016). Multimeter + Distortion Analysis + 9.5V Audio Generator + Harmonics (Model 2016-P). Multimeter resolution: 6.5 digit. Basic Multimeter Accuracy (DCV): 0.002%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 100 µΩ to 100 MΩ. Speed: 2,000 measurements per second. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), frequency, period, temperature (using thermocouples), diode test, open detection, dB, dBm. The built-in distortion analyzer measures: THD, THD+Noise and SINAD. The built-in harmonic analyzer measures individual harmonic levels. Audio analyzer frequency range: 20 Hz - 20 kHz. Five standard audio filters. Interfaces: IEEE-488.2 (GPIB), RS-232. Weight: 4.2 kg. An excellent tool for developing and configuring devices in the audio range |
Multifunctional data acquisition and control systems of the Keithley brand | ||
Keithley DAQ6510 |
Product code: 1000684 |
Keithley DAQ6510 Laboratory Multimeter with Integrated Data Acquisition, Switching and Channel Scanning Resolution: 6.5 digit. Basic Accuracy (DCV): 0.0025%. Voltage measurement range: 0.1 µV to 1010 V. Current measurement range: 10 pA to 10.1 A. Resistance measurement range: 1 µΩ to 120 GΩ. Capacitance measurement range: 0.1pF to 120uF. Digitization of voltage and current signals: 16 bits (from 1 kS/s to 1 MS/s). 12 types of switching and control modules. Possibility to install two modules. Depending on the type, the modules may contain: a switch for 20, 32 or 40 input channels, 16 digital and 2 analog control outputs, a 6x8 arbitrary switching matrix, a 3.5 GHz microwave switch, etc. The maximum number of channels: 80. 15 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire), capacitance, period, frequency, diode test, temperature (using thermocouples, thermistors and RTDs), etc. Free computer software, drivers LabVIEW, IVI-C, IVI-COM. 12.7 cm widescreen touchscreen (800 x 480 resolution). Weight: 4.54 kg. Interfaces: Ethernet/LXI and USB (standard); IEEE-488.2 (GPIB), RS-232 and TSP-Link (optional). Multifunctional data acquisition system with 6.5 digit multimeter |
Keithley 2700 2701 2750 |
Product code: 1000693 |
Keithley 2700, 2701, 2750 laboratory multimeters with built-in data acquisition, switching and channel scanning Resolution: 6.5 digit. Basic Accuracy (DCV): 0.002%. Voltage measurement range: 0.1 µV to 1000 V. Current measurement range: 10 nA to 3 A. Resistance measurement range: 1 µΩ to 100 MΩ. Speed: 3,500 measurements per second. 12 types of switching and control modules. Model 2700, 2701 can install up to two modules, model 2750 up to five modules. Depending on the type, the modules may contain: a switch for 32 or 40 input channels, 16 digital and 2 analog control outputs, a 6x8 arbitrary switching matrix, a 3.5 GHz microwave switch, etc. The maximum number of channels: 200. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, "dry contact"), frequency, period, temperature (using thermocouples, thermistors and RTDs), break detection, etc. Interfaces: IEEE- 488.2 (GPIB) (on models 2700, 2750), Ethernet (on model 2701), RS-232. Compact measuring system with the possibility of switching and control |
Keithley 3700A |
Product code: 1000694 |
Keithley 3700A Series Lab Multimeters with Integrated Data Acquisition, Switching, and Channel Scanning Resolution: 7.5 digit. Basic Accuracy (DCV): 0.002%. Voltage measurement range: 10 nV to 300 V. Current measurement range: 1 pA to 3 A. Resistance measurement range: 100 nΩ to 120 MΩ. Speed: 14,000 measurements per second. 10 types of switching and control modules. The Model 3706A accepts up to six modules. Depending on the type, the modules may contain: a switcher for 20, 30 or 40 input channels, a multifunctional control unit, a 6x16 or 4x28 random switching matrix, etc. The maximum number of channels: 576. Several 3700A series units can be interconnected and controlled as one device. 13 types of measurements: DC and AC voltage and current, resistance (2-wire and 4-wire, "dry contact"), frequency, period, temperature (using thermocouples, thermistors and RTDs), break detection, etc. Interfaces: USB- TMC, IEEE-488.2 (GPIB), Ethernet. Powerful measuring system with switching and control capability |
Calibrators - multimeters (SMUs) of the Keithley brand | ||
Keithley 2450 |
Product code: 1000695 |
Keithley 2450 Touch Calibrator Multimeter (SMU) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 500 nV to 200 V (generation), 10 nV to 210 V (measurement). Current: 500 fA to 1 A (generation), 10 fA to 1.05 A (measurement). Resistance: 1 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). Speed: up to 3,130 measurements per second. Formation of a series of control points. Free PC software and drivers LabVIEW, IVI. 12.7 cm widescreen touchscreen (800 x 480 resolution). Interfaces: IEEE-488.2 (GPIB), Ethernet/LXI, USB, TSP-Link. Weight: 4.04 kg. Convenient, accurate and affordable touch-controlled device |
Keithley 2401 |
Product code: 1000696 |
Keithley 2401 Multimeter Calibrator (SMU) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 20 V (generation), 1 µV to 21 V (measurement). Current: 50 pA to 1 A (generation), 10 pA to 1.05 A (measurement). Resistance: from 100 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 3.21 kg. Inexpensive Low Voltage Calibrator Multimeter (SMU) up to 20V |
Keithley 2400 2400-C |
Product code: 1000697 |
Keithley 2400 and 2400-C SMU Calibrators Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 200 V (generation), 1 µV to 210 V (measurement). Current: 50 pA to 1 A (generation), 10 pA to 1.05 A (measurement). Resistance: from 100 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Automatic testing of connection contacts (Model 2400-C). Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 3.21 kg. Basic calibrator-multimeter (SMU) for a wide range of applications |
Keithley 2410 2410-C |
Product code: 1000698 |
Keithley 2410 and 2410-C High Voltage Calibrators/Multimeters (SMUs) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 1000 V (generation), from 1 µV to 1100 V (measurement). Current: 50 pA to 1 A (generation), 10 pA to 1.05 A (measurement). Resistance: from 100 µΩ to 200 MΩ (measurement). Output power: up to 20 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Automatic testing of connection contacts (Model 2410-C). Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 3.21 kg. High voltage multimeter calibrator (SMU) up to 1000 V |
Keithley 2425 2425-C |
Product code: 1000699 |
Powerful (up to 100 W) Keithley 2425 and 2425-C Calibrators/Multimeters (SMUs) Resolution: 6.5 digit. Basic Accuracy (DCV): 0.012%. Voltage: 5 µV to 100 V (generation), 1 µV to 105 V (measurement). Current: 500 pA to 3 A (generation), 100 pA to 3.15 A (measurement). Resistance: 10 µΩ to 20 MΩ (measurement). Output power: up to 100 W. 4-quadrant operating area (voltage/current generation or load operation). 2-wire, 4-wire and 6-wire connection scheme. Speed: up to 2,081 measurements per second. Built-in pass/fail comparator for automatic rejection. Ability to automatically generate a series of control points. Automatic testing of connection contacts (Model 2425-C). Free PC software and LabVIEW driver. Interfaces: IEEE-488.2 (GPIB), RS-232, Keithley Trigger Link. Weight: 4.1 kg. Powerful multimeter calibrator (SMU) up to 100 W |
Parametric Analyzers of the Keithley brand | ||
Keithley 4200A-SCS |
Product code: 1000702 |
Keithley 4200A-SCS Parametric Analyzer Current-voltage characteristic (CVC) range: up to 210 V, up to 1 A. Capacitance-voltage characteristic (CVC) frequency range: from 1 kHz to 10 MHz. Pulse current-voltage characteristic range: ±40 V, ±800 mA, 200 MSa/s. Current resolution: up to 0.1 pA. Connection diagram: 2-wire and 4-wire. Allows you to measure the I-V characteristics, the complex resistance to alternating current, register signals and measure the I-V characteristics of transients. 39.6 cm color touch screen (1920 x 1080 resolution). Interfaces: USB, Ethernet (LAN), IEEE-488.2 (GPIB), RS-232, SVGA. Weight: 29.7 kg. Dimensions: 436 x 223 x 565 mm. Working temperature: from +10°С to +40°С. Accurate characterization of semiconductors and materials |
Laboratory power supplies of the Keithley brand | ||
Keithley 2220 |
Keithley 2220 Transformer bipolar power supplies Two outputs: 30 V, 1.5 A, 45 W (models 2220-30-1 and 2220G-30-1). Two outputs: 30 V, 1.5 A, 45 W+ third output: 6 V, 5 A, 30 W (model 2230-30-1 and G). Number of channels: 2 or 3. All channels galvanically isolated. Possibility of parallel and serial connection of channels. Possibility of compensating the voltage drop in the connection wires. Very high accuracy and high resolution (1 mV and 1 mA). Interfaces: USB (standard), IEEE-488.2 (GPIB) (on 2220G and 2230G models). Weight: 8.2 - 8.5 kg (depending on model). Dimensions: 105 x 242 x 384 mm. 2- and 3-channel power supplies with isolated outputs |
|
Keithley 2290E-5 2290-10 |
Product code: 1000573 |
Keithley 2290 High Voltage DC Power Supplies Voltage: up to 5 000 V, current: up to 5 mA (model 2290E-5). Voltage: up to 10 000 V, current: up to 1 mA (model 2290-10). Number of channels: 1. Current measurement with a resolution of 1 μA. The presence of filters to reduce the output noise to 3 mV per 5 kV. Safe high voltage output control mechanism. Interfaces: IEEE-488.2 (GPIB) (standard) and RS-232 (on Model 2290-10). Weight: 3.7 - 5.5 kg (depending on model). Dimensions: 89 x 206 x 406 mm. Precise and safe generation of high voltage |
Functional signal generators of the Keithley brand | ||
Keithley 3390 |
Product code: 1000753 |
3390 Special Waveform and Arbitrary Waveform Generator Frequency: up to 50 MHz. Resolution: 14 bit. Sampling: 125 MS/s. Memory: 256K dots. Channels: 1. Output voltage: 20V. Waveforms: 12 standard waveforms. Modulation: AM, FM, FM, PWM, FSK. Interfaces: IEEE-488.2 (GPIB), LAN, LXI-C, USB. |
Pulse and pattern generators of the Keithley brand | ||
Keithley 3401-F 3401-R 3402-F 3402-R |
Product code: 1000754 |
3400 Series Pulse and Pattern Generators Frequency: up to 165 MHz. Number of channels: 1 (model 3401), 2 (model 3402). Output signal amplitude from 100 mV to 20 V. Memory: 16 Kbps per channel. Data formats: PRBS 2^n-1, n=5-14; rz, nrz. Independent rise and fall times. Output locations: on the front panel (suffix -F), on the rear panel (suffix -R). Interfaces: IEEE-488.2 (GPIB), USB. |
Economy offer
Tehencom company offers both completely new devices, as well as used and fully restored in the factory. The cost of refurbished devices can be 1.5 - 2 times lower than the cost of new ones. All proposed refurbished devices are 100% operational, meet the technical requirements of the manufacturer and are provided 1 year warranty.
Below are some of the many refurbished instruments we offer.
Model | A photo | Short description |
Multimeters of the Keithley brand (refurbished) | ||
Keithley 2000 |
Desktop multimeter. 100 mV - 1 kV. 6.5 digit. Accuracy: 0.0015%. DCV, ACV, R, wire break, diode, DCA, ACA, TRMS. |
|
Keithley 2700/2701 |
Desktop multimeter. 100 mV - 1 kV. 6.5 digit. Accuracy: 10ppm. DCV, ACV, R, DCA, ACA, frequency, temperature. Control and registration modules. |
|
Keithley 2010 |
Desktop multimeter. 100 mV - 1 kV. 7.5 digit. Accuracy: 10ppm. DCV, ACV, R, DCA, ACA, frequency, period, temperature. |
|
Keithley 2750 |
Desktop multimeter. 100 mV - 1 kV. 6.5 digit. Accuracy: 10ppm. DCV, ACV, R, DCA, ACA, frequency, temperature. Control and registration modules. |
|
Keithley 2015 / 2016 |
Desktop multimeter. 100 mV - 750 V. 6.5 digit Accuracy: 30ppm. DCV, ACV, DCA, ACA, frequency, diode, temperature, harmonic distortion. |
|
Keithley 2001 |
Desktop multimeter. 200 mV - 1 kV. 7.5 digit. Accuracy: 27ppm. DCV, ACV, R, DCA, ACA. |