Thermal imagers

Thermal imager (thermal imaging camera) – this is a device for monitoring the temperature distribution of the surface under study. The temperature distribution is displayed on the display (or memory) of the thermal imager as a color field, where a certain color corresponds to a certain temperature. As a rule, the display shows the temperature range of the surface visible through the lens. Typical resolution of modern thermal imagers reaches 0.1°C.

Thermal imagers excel in finding overheated parts of electrical installations, in detecting heat leaks in building structures and in many other applications. In this catalog of the Czech company Workswell, which specializes in the development and production of thermal imaging systems, you can see a variety of practical tasks that are effectively solved using these devices:

Workswell Catalog 2020 (English) (36 pages; 23 MB)

Below are the most popular models of thermal imagers. Regarding prices and delivery times for the entire range of instrumentation, simply call us or write to us at E-mail and we will be happy to answer your questions.

Model A photo Short description
Thermal Imagers of the Workswell company
Workswell
MEDICAS
Workswell MEDICAS - medical thermal imaging system for the detection of people with fever

Product code: 1000731

Medical Thermal Imaging System Workswell MEDICAS
Resolution: 640 x 512.
Measured temperature: from 0°С to +50°С.
Temperature measurement accuracy: 0.3°C. Temperature sensitivity: 0.03°C.
Designed to detect people with fever. Processes the stream of faces in real time. Complies with ISO/TR 13154:2017.
Permanently calibrated to black body BB90 (included).
Contains a combined video camera with a resolution of 1920 x 1080.
Interfaces: Ethernet, USB, HDMI, etc. Weight: 0.5 kg.
Dimensions: 83 x 85 x 68 mm. Working temperature: from +15°С to +30°С.
Non-contact detection of people with fever
Thermal imagers of the Fluke company
Fluke
Ti50FT
Ti55FT
Fluke Ti50FT, Ti55FT - Thermal Imagers for the Electro-Mechanical Industry

Product code: 1000732

Thermal imagers for the electro-mechanical industry Ti50FT, Ti55FT
Resolution: 320x240.
Measured temperature: from -20°С to +350°С (model Ti50FT).
Measured temperature: from -20°С to +600°С (model Ti55FT).
Temperature measurement accuracy: 2°С. Temperature sensitivity: 0.05°C and 0.07°C. Image Refresh Rate: 60Hz. The maximum set of functions. Excellent image quality. Saving images and sound comments to them on an internal flash card. Weight: 1.95 kg.
Fluke
Ti27
Ti29
Ti32
Fluke Ti27, Ti29, Ti32 - Thermal Imagers for the Electro-Mechanical Industry

Product code: 1000733

Thermal cameras for the electro-mechanical industry Ti27, Ti29, Ti32
Resolution: 240x180 (model Ti27).
Resolution: 280x210 (model Ti29).
Resolution: 320x240 (model Ti32).
Measured temperature: from -20°С to +600°С.
Temperature measurement accuracy: 2°С. Temperature sensitivity: 0.05°C. Image refresh rate: 9 or 60 Hz (depending on modification). Excellent image quality. Saving images and sound comments to them on an internal flash card. Weight: 1.05 kg.
Fluke
TiR27
TiR29
TiR32
Fluke TiR27, TiR29, TiR32 - Thermal Imagers for Construction

Product code: 1000734

Thermal imagers for construction TiR27, TiR29, TiR32
Resolution: 240x180 (model TiR27).
Resolution: 280x210 (model TiR29).
Resolution: 320x240 (model TiR32).
Measured temperature: from -20°С to +150°С.
Temperature measurement accuracy: 2°С. Temperature sensitivity: 0.04°C and 0.045°C. Image refresh rate: 9 or 60 Hz (depending on modification). Excellent image quality. Saving images and sound comments to them on an internal flash card. Weight: 1.05 kg.
Fluke
Ti10
Ti25
Fluke Ti10, Ti25 - Thermal Imagers for the Electro-Mechanical Industry

Product code: 1000735

Thermal imagers for the electro-mechanical industry Ti10, Ti25
Resolution: 160x120.
Measured temperature: from -20°С to +250°С (model Ti10).
Measured temperature: from -20°С to +350°С (model Ti25).
Temperature measurement accuracy: 2°С. Temperature sensitivity: 0.09°C and 0.13°C. Image refresh rate: 9 Hz. Saving images to an internal flash card. Weight: 1.2 kg.
Fluke
TiS
Fluke TiS - Building Thermal Imager

Product code: 1000736

Thermal imager for construction TiS
Resolution: 120x120.
Measured temperature: from -20°С to +100°С.
Temperature measurement accuracy: 5°С. Temperature sensitivity: 0.1°C. Image refresh rate: 9 Hz. Saving images to an internal flash card. Low cost. Weight: 1.2 kg.

Economy offer

Tehencom company offers both completely new devices, as well as used and fully restored in the factory. The cost of refurbished devices can be 1.5 - 2 times lower than the cost of new ones. All proposed refurbished devices are 100% operational, meet the technical requirements of the manufacturer and are provided 1 year warranty.

Below are some of the many refurbished instruments we offer.

Model A photo Short description
Thermal imagers of the Fluke company (refurbished)
Fluke
Ti40
Ti45
Ti50
Ti55
discontinued
Fluke Ti40, Ti45, Ti50, Ti55 - Thermal Imagers for the Electro-Mechanical Industry

Product code: 1000737

Thermal imagers for the electro-mechanical industry Ti40, Ti45, Ti50, Ti55
Resolution: 160x120 (models Ti40, Ti45).
Resolution: 320x240 (models Ti50, Ti55).
Measured temperature: from -20°С to +350°С (models Ti40, Ti50).
Measured temperature: from -20°С to +600°С (models Ti45, Ti55).
Temperature measurement accuracy: 2°С. Temperature sensitivity: 0.05°C to 0.09°C. Image Refresh Rate: 60Hz. Saving images to an internal flash card. Weight: 1.95 kg.
Out of production. Replacement: Fluke Ti50FT, Ti55FT.
Fluke
Ti20
Ti30
discontinued
Fluke Ti20, Ti30 - Thermal Imagers for the Electro-Mechanical Industry

Product code: 1000738

Thermal imagers for the electro-mechanical industry Ti20, Ti30
Resolution: 128 x 96 (model Ti20).
Resolution: 160x120 (model Ti30).
Measured temperature: from -10°С to +350°С (model Ti20).
Measured temperature: from -10°С to +250°С (model Ti30).
Temperature measurement accuracy: 2°С. Image refresh rate: 9 Hz. Save up to 100 images. USB interface. Weight: 1.2 kg.
Out of production. Replacement: Fluke Ti32.